|
CONTACT US |
Address:
720 CaiLun Road,Bldg No.2 Room 101 Zhangjiang Hi-Tech Park Shanghai,China
|
| Postcode: 201203 |
| Fax:021-50790893 |
| Tel:021-50791619,50790895 |
|
|
|
| INSTRUMENTS |
| |
 |
 |
ELISA 96 Well Reader |
318MC Microplate Reader is adopted the most advanced technology, It succeeds several times in the bid of overseas of domestics. It can be used in research field such as, diagnostic in hospital, immunopathology analysis, antigen and antibody analysis of microbiology, diagnostic of parasi-tosis, mensuration of dysendocrinism, research of plant disease.
|
|
|
 |
 |
ELISA Portable Battery Operated Strip Reader |
Long lamp life Long life span of lamp (approx. 10,000hours)
Safe power source 6VDC
Filter 450mm
Display range 0-3.5 Abs
Photometer range 0-2.000 Abs
Accuracy ±2.0% or ±0.007 Abs
Lineality ±2.0% or ±0.007 Abs
Microplate Strips 8 or 12
Weight 0.33Kg
Dimensions 180mm x 84mm x 70mm |
|
|
简单的.jpg) |
 |
CLIA 96 Well Reader |
Chemiluminescence analyzer is usd to annlyze the content of biochemical material in a chemiluminescence mode. There is no need for an external computer, as sample’s testing and analysis can be accomplished by it self. This analyzer supports 96-micropore microporous board and can be widely used in the areas of luminescence immunization analysis.
|
|
|
带电脑的.jpg) |
 |
CLIA 96 Well Reader with built in computer |
|
 |
 |
Battery Operated Portable Luminometer |
Long life span of lamp (approx. 10,000hours)
In addition to the measurement with square cuvette
Round cuvette also can be used with a supplied adaptor
6VDC or 220VAC
On setting the concentration mode with standard, curve drawing of each analysis is eliminated and direct reading is enabled
Durable large glass filters of ∮8mm(Diameter) and a new silicone photo-diode enables high electric stability
That offers accurate and reliable measurement results
Possible to output the results to the recorder using supplied analog output cable.
RS-232
Development of small and high performance silicone photo-diode and advanced electronic
Circuit realized a space-saving bench top model in 2Kg net weight and 180(W)*84(D)*60(H) mm size. |
|
|
 |
 |
ELISA Washer |
The washer is the new product of our company, Comparing to the same type of the product inland or oversea, it possesses the characters such as simple operation, good performance of washing, handy maintenance, etc. It can be used for the clinical immunoassay in the hospital or education in the academe. |
|
|
 |
 |
Clinical Chemistry Analyzers |
The analyzer is an automation analysis system which has the function of biochemistry analysis, data handling, standard reporting, connecting internet. It has color monitor, Chinese Operation System and opening-reagent. It not only has the function of biochemistry and also has the function of standard personal computer.
|
|
|
![]() |
 |
Lateral Flow(One-Step) Reflectance Reader |
A low-cost, simple strip reader system using a linear movement mechanism of CD-ROM deck has been developed to characterize a lateral flow membrane-based immunochroma-tographic assay. The test strip reader was assembled by a CD-ROM deck and home-made optical head especially designed for immunoassays. The optical head for detecting reflected light from the test strip surface consists of green light-emitting diode, large area silicon photodiode, and anodized aluminum mounting block providing a slit structure for cutting light from the LED. The stepping motor of the deck was operated in the full step mode, whose distance of each reading point is about 0.15 mm. The performance of the strip reader was tested by analysis of HBV (hepatitis B virus) antigen test kit. This strip reader can be useful for inexpensive, disposable, and membrane-based assays that provide visual evidence of the presence of an analyte in a liquid sample. |
|
|
![]() |
 |
Fluorescence Reflectance Reader |
A novel setup for fluorescence measurements of surfaces of biological samples, in particular the plasma membrane of living cells, is described. The method is based on splitting of a laser beam and multiple total internal reflections (TIR) within the bottom of a microtiter plate (cell substrate), such that up to samples are illuminated simultaneously by an evanescent electromagnetic field. Main prerequisites are an appropriate thickness and a high transmission of the glass bottom, which is attached to the cell culture plate by a noncytotoxic adhesive. Glass rods of rectangular cross sections are optically coupled to this bottom for TIR illumination.
|
|
|
 |
 |
Urine Chemistry Strip Readers |
Automatic test strip recognition and standby
Enter data via keyboard or barcode reader
Variable format selection for printout of test results and time/data
Adjustable concentration ranges, grades and units
Automatic transport, measurement of test strips
|
|
|
 |
 |
Urine Chemistry Strip Readers |
Urine colour compensation
Enter data via keyboard or barcode reader
Variable format selection for printout of test results and time/data
|
|
|
|
|
|